Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we inject a standard 6 times for Related substances by
HPLC and 5 times for Assay?

Answer Posted / dattatray bankar

As in RS std conc. is too low as compare to assay and to
minimize deviation in area we determine SD. as no of inj.
increases SD decreases and we get the %RSD within limit.

Is This Answer Correct ?    40 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Which type of column should i use to check the purity of high molecular weight protein using HPLC reverse phase column chromatography? Hi everyone. I wanna to check the purity of high molecular weight protein (collagen) with MW of ~130 kDa using a HPLC. I know C18

1907


some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?

2644


how we can identify the impurity is coming below loq at transfering site?

858


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

820


identification is for unknown? qualification for known? reporting for LOQ?

716


From where require to take the RLD sample?

747


What are the primary considerations in extractables and Leachables ?

2267


analytical method validation require to with respect to release specification or shelf life specification?

780


why require to add enzymes in capsules dissolution only? is it require to tablet also?

674


if content uniformity passing but dissolution varrying then what is next step?

861


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2688


What is related substance by HPLC impurity limits as per USP?

1090


What is third generation HPLC Columns?

1973


1)What's the meaning of Absorption,give a example. 2)What's the meaning of Adsorption,give a example. 2)what is the difference between Absorption and Adsorption.

2876


how you start the solubility study?

812