Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is primary solution and secondary solution

Answer Posted / devendra kumar

primary solution is that we get as stock solution, while
secondary solution is that we use as working solution for
defferent analysis

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1596


UV and PDA detector, which have less signal to noise ratio?

1132


what is the disso medium for tropsiun chloride

2260


Ratio of Water and Acetonitrile(diluent) is not recommended to use in cleaning method validation,why?

2963


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3178


why does used dry caffien in HPLC calibration?

2032


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2728


How to calculation of residual solvent methanol (3000 ppm) standard solution, and how many quantity used of test sample

3238


WHAT IS THE PARAMETER FOR THE SELECTION OF MOBILE PHASE IN HPLC?

1185


if instrument calibration fails then what require to do?

980


Why we check moisture,ash & AIA in product

1876


how will you do the prep for unstable componds?

2024


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2576


In HPLC (Waters) software Empower1,2 &3 what is the updation for each version

3032


If vendor having more imp than monograph then how to proceed? and how to set spec?

933