Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

We have .ht motor which is 60Hz.we run on 50Hz.so that it's speed reduce
but we had one prob.that motor winding temp increase up to 135 deg.we
want reduce this temp.what to do?we arrange ext.cooling fan but not much
effect.we want reduce this temp. Inhouse without affecting much.cost. also
don't want reWINDING OF MOTOR?

Answer Posted / r c thakur

You have to increase the surface area of the motor,the
radiator fins can be introduced,

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What happen when neutral point connected to core balance current transformer? (Neutral point of an alternator of a 180KVA DG. Neutral point connected to CBCT means enter to the CBCT)

2299


How could a garment factory benefit from renewable energy

2770


What is the comparison of PILC and XLPE cable

2151


What is the mmf,rgt and ngt please brief completely

1637


how to calculate cable size in diffrent loads?

2086


Hi.. I am a BE GRaduate in E&E. I have 8.5 Experience in Tendering & Estimation field. I have done SAP SD course few years back. But due to some reason i failed to get job in that field and continued my own field. Now I am thinking of changing into SAP seriously. How should i go ahead???

1959


Why single phase induction motors are not self starting ?

1662


DG cranking voltage?

4763


How do we calculate over and under frequency tolerance from generator data?

1621


why the pf of semiconductor device is improved the electrical devices

1847


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2154


explain with diagram how to protect transformers and substations from over current with help of CT's?

1968


how to calculate mf when meter and cTPT detail are given

1846


WHAT IS SITTING AMPS IN OVER-LOAD RELAY FOR 1PH OR 3PH MOTORS?IF ITS NAME PLATE GIVEN MAX AMPS 10AMPS?

1762


What is the drawback of static coefficients?

1624