Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why caffeine as a reference standard used for calibration
of HPLC?

Answer Posted / irfan shaikh

n it shows maximum absorbance at 273nm

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

848


how to set sample and standard concentration in RS method?

840


Which is the highly polar and highly non polar column in HPLC?

2239


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1555


what parameters we will consider while developing a HPLC method and how we confirm our HPLC method is valid?

3630


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

2662


why we are using benzene, anyline in acetic anhdride assay titration method?

2063


Why we used in n-butyl acetate water content terminology while in ethyl acetate we used moisture content terminology?

1796


Difference between hlaf and rlaf

2057


in monograph 7 imp are there but in vendor showing 5 imp do not req to include 2 imp for that what will be justification?

665


IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?

2393


which situation gc hs and gc als require to use?

721


if you given one product then which tests you will perform?

664


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1547


what is turbidimetric titration?Give 2 examples.

2580