Answer Posted / rajesh.kon
always field(Process) instruments are communicated or
connected with PLC, DCS system.those PLC, DCS operating
current is 24 Vdc, so that instrument which are connected with
DCS, PLC system will be also using 24Vdc only.
| Is This Answer Correct ? | 5 Yes | 6 No |
Post New Answer View All Answers
What is intrinsically safe system?
Pressure tx shows 1 mbar but we need 1000 mbar at this process condition .. how can we sort it out .
send me last 5 years questions asked in rrb chennai, for section engineer
Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?
Tr. Wiring for calibration.
protection relay watchdog contact operation?
what is piezoelectric transducer?give an example in power plant n state its principle?
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell
full process of gas turbin?
In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.
What is shielding effect?
how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
how u calibrate pneumatic n motorized c/v?