Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why there is no provision of breaker in between primary of UAT and generator

Answer Posted / 7anoter4

I think, it does not need a UAT breaker since if the UAT
does not supply power to the generator auxiliary the
generator will shut down, any way. So, the generator
breaker will protect the UAT also. Providing a UAT breaker-
not taking into consideration the expenses-it could be an
other generator failure point if this breaker would fail or
would open unmotivated.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

HOW WE CAN REDUCE THE CIRCUIT COMPLEX OF STAR-DELTA STARTER .BECAUSE NOW WE USING ONE TIMER RELAY & THREE CONTACTOR FOR MAIN,STAR & DELTA ?IF ANY IDEAS PLZ POST.THANK U

2502


while doing high potential for 11KV 3 core cable how much leakage current will obtain?, what will be acceptance value?

2887


A jet of fluid strikes a plate What was the force required to counter it?

1875


which type of motor is used in automatic swing gate

2012


I want to do a mini project. Now I'm studying in 6th semis tor EEE Engineering.

2155


Can you explain about pole discrepancy scheme

2183


The power factor of the fixed load is 0.8, now the p.f is varying from 0.8 to 0.5.

1987


1.what is meaning of curve into a mcb. 2.what is basic reason changing of curve

2000


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1969


An automatic water heater is an example of which type of control system?

1167


Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?

2126


I have been using an 600VA with 0.6 p.f UPS with my desktop which has 450W power supply unit. Can anyone explain how can this happen . Because the output of the UPS is 360W (600*0.6) (<450W)

2135


is it value of power factor is more than unit. whats effects in the source supply

2075


List out the the types of Mounting Light fixture?

1612


WHICH SIZE A.B.CABLE IS USED FOR 11KV.

2202