What is actuator what is motorized control valve?
Answer Posted / arun
Acuator is a part of valve, which is used for opening of
valve
control valve which is required electrical voltage for
operation.
| Is This Answer Correct ? | 4 Yes | 4 No |
Post New Answer View All Answers
Which tank weighing system is better to install (Accuracy point of view) 1) Tank weighing system with 3 load cell or 2) Tank weighing system with 4 Load cell
how to work static pressure sensore how to work dpt
what do u mean by compensation n pid tunning?in pid tunning what you tunned?is it possible 2 tune p i d
in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.
Please send me the sample question of Instrumentation of hpcl/iocl exam. my mail id hihi_kiholo@rediffmail.com
Can any body tell me about SAP MAINTINANCE MODULE. WHAT IS its function and application. And study material Source about it. I shall be very thankful.
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
why fuse block is not used for AI signal?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
what is the difference between scaler and vector drive
What is the use of GMV in turbine?
where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve
anybody having Qatar Petroleum questions for instrument Technician offshore ....please send me
what are the values of fuel flow rate in various places in boiler.
How to Calibrate Level Troll in field