Why mostly GT(Generating Transformer)has only Ynd1 Vector
Group?
Answer Posted / yu
provision for low voltage side with NGR
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
Disadventage of cable-gland earthing if any ?
what is the difference b/w pvc cu conductor and cu breaded wire..?
how i calculate the syncrones generator NGR resistance .if we have a 6mw generator line voltage of generator 11kv also line current 393.3 ampere.
What are the criteria shall be considers for sizing Fuse and MCB? If the rated current is 10Amps what should be the fuse size / MCB Size?
How to calculate per unit impedance of transformer?
How is the gain affected by the introduction of feedback in a control system.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How to check 11000/1.732 to 110/1.732 Potentila transformer (PT)?
pls tell me function of closing coil of A.C.B.
why a tester wont shock while testing the power in house
HOW WE CHOOSE EARTH'S POTENTIAL AS ZERO V?
Define Electrical Insulation and examples of Solid,Liquid and Gaseous insulating materials?
what is the terminal voltage of dc series generator running at rated speed at no load?
what is a vector protection in transformer