Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHY THE FREQUENCY IS 50 HZ IN INDIA.CAN WE USE SOME OTHER
FREQUENCY.IF SO WHAT IS THE RANGE AND WHAT WILL BE THE
EFFECT IN PRESENT POWER SYSTEM IF WE CHANGE THE FREQUENCY
AS YOU SUGGEST ?

Answer Posted / ram

actually our generation design is for 50 hz thats why india follow 50 hz and our equipement also design for same if we want to change the frequency we need to change the all electrical equipment

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?

1755


how do u gauge the size of the cable ?for eg. consider a 300 sqmm L.T Cable.How do u determine the size of the cable seeing it pratically?

2102


Electrical Engineering

2053


What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.

2180


how to select automotive wire by mathematical equation with given current, vlotage and resistance

2346


what is cascade speed control device?and how this device control the speed of motors?

2145


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9189


A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?

2429


why Induction Generators are not "Black start" ? and apart from WTGs where this types of generator are generally used?

2640


How to calculate the copper in HT motors if KW, RPM & Voltage is given

3197


what will happen if synchronous machine rotor fed from single phase ac supply 

1731


What is difference between slip rings and carbon burushes?

15085


Hoe do calculate the Cable size for Amps rating ?

2148


if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .

1657


Why in 6 KV XLPE cable termination kit used and why not in 380 V xlpe cable same is not used

2626