What should be the neutral and body grounding sysytem for
grid (132 KV) parallel generators (440 volts)?
Answer Posted / g ravikanth
Grounding means its a path for returning current, due to imbalance of phase currents there will be a return current after balancing phase sequence in the Generator.
| Is This Answer Correct ? | 0 Yes | 6 No |
Post New Answer View All Answers
Which will have more strain energy 1.Spring 2.Circular disc 3.Solid square plate.
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
what is the basic use of power plant in equipment
what is the difference between compensated & normal drum level in boiler drum?
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
How We Calibrate the vaccum transmitter?
im try to calculating seawater flow required for SW-FGD system. I need a guide, equation or method to do it, can some one help me! Thanks very much
can u please tell me how to calculate the concrete quantity for a under reamed pile? r=300mm,depth=3m for a cylinder and for bulb l=.750mm,width=.525
dear sir i have completed one year post diploma certificate in thermal power engineering from national power training institute durgapur ...plz suggest me for power sector job
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
how to differentiate between "ALL fuel lost" and "All Fuel Lost" in Boiler MFT condition?
what is restricted earth fault explain in details
Looking for Bently Nevada surplus 3300/52-01-00-00 Reverse Rotation Monitor , 4 pieces.
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
LAPT working in alternator / generator