Active power= VI COS FI But incase of leading power factor ( more than unity), may we use other formula ? because the cos fi (value of cos thita) should not be grater than one.
Answer Posted / biswaindu parida
Power factor is never more that unity.
Why?
Power factor is leading is nothing but current is leading the voltage. In a 360 deg case stude anything 30 deg leading means it is 330 deg lagging in other direction.
remember current does not actulally leds voltage, it lags by 330 deg which we say in other words as leading 30 deg for easy understanding purpose.
so instead of cos(30) if u will right cos(-330) it is same. so there is no such case of pf >1 in case of leading case.
Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
What is electrical cable termination
In case of salient pole alternator when number of poles are 4 or more than 4 it helps the flux wave to be sinusoid as air gap length is increased from center to tip , but if the number of poles are 2 how does the flux wave is sinusoidal?
How to measure size of cable on a given load
what is the benefit of floating our DC source? if i have two floating DC source of which 1 has a ref voltage of -21VDC and the other of -18VDC. can it be connected in parallel to share a common ref voltage? if not, how do i make both sources to be of common ref voltage? tks
what is the difference between earth leakage and earth fault?
what is the preventive maintence for ht panels and busbars and vcb abd acb's.
Why only sinusoidal ac voltages are generated?why not triangular or sawtooth?
Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you
please send me the L&T Emb. sys. placement papers and entire details of pattren
What is the method of estamating of cable, CB,MCB ?
what is zinc diffusion?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
I am applying for NTPC examination.Can we please provide previous paper to my mail prasad.chintala108340@gmail.com
I have iti elec, 1st aid, and 5 yrs experience in 7.5 mw power plant. Am i eligeble for 11kv license in telangana state..when, how to apply for that.?
which network topology offers the greatest level of tolerance?