Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is maximum AC & DC transmission voltage in India? and
where?

Answer Posted / muralikrishna pilla

at present the highest ac transmission voltage is 765 kv now
in 12 th commission try to changing that one to 1200kv.the
hvdc is now 500kv trying to change to 800kv which is worlds
biggest project.....

Is This Answer Correct ?    24 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?

2147


Can we test the alignment of End shield and stator of turbogenerator without rotor insertion? Also how to fix maintain the alignment at site installation?

2282


We have 5 Distribution sections with variable loads&We have 3 Gensets(500kva,380kva&250kva) our total load is between 400kva to 600kva. so how could we connect 3gensets.

1800


for 750 kw LT load what will be the ht kva

1593


sir please send me previous year questions of jspl of electrical section through which i could prepare myself fpr the test.

1859


delta motor winding resistance I take normally single winding is 2.5, which value is came delta connection ie RY ?

1942


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2090


what are the pecularity of shaver sockets ?

1860


how open delta PT works & what is its construction?

2189


why is the power generator connected as star earthed or star earthed through reactance and what its features ?

1605


if 6 earth pit value is 1.5 ohm then what should be the number of earth pit to make the value .8 ohm

2159


how works inductive &capacitive sensors?

1912


how to setting Load amps tripping time and extra settings for load Transformer protection relay with RMU panel using C&S model relay..?

1070


what is the effect of change in supply frequency on load angle of synchronous motor,all other parameters remaining same?

2295


why the India electrical supply transmission loss is high when compare to us

1924