WHAT IS THE DIFFERENCE BETWEEN PLC AND DCS
Answer Posted / rajaram
NOW DAYS THERE ARE NO MORE DIFFERENCE IN PLC & DCS,
BASICALLY PLC ARE USED REDUCED NO OF ELECROMAGNETIC RELAY &
dcs IS USED FOR REDUCED pid CONTROLLER.
NOWDAYS PLC ARE SUING FOR SEQUENCIAL CONRROL I.E ESD AND
OTHER SAFETY RELATED SPECIFIC SYATEM OND OTER HAD DCS IS
BEING USED FOR CONROL OVER ALL PLANT AT ONE PLACE USING V
NET(YOKOGWA SYSTEM) OR DELTA v(EMERSON).
PLC TAKES LESS TIME TO CONTROL THE PROCESS MEANS CONTROL
ACTION HOWEVER IN CASE OF DCS IT TAKES MORE TIME.
IN DCS DIFFERENT PLC CAN DO COMMUNICATE EACHOTHER AND DCS
EXECUTED CONTROL ACTION BY OPERATOR THROUGH FUCNTION BLOCK
AND IN plc IT IS FERFORMED BY LADDER.
PLC ARE NOT PROPRIETARY SYSTEM HOWEVER DCS PROPRIETARY
SYSTEM .
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
what is the calibration procedure for magnetic flow meter @ onsite
In my company plc based winders are operated. one day there was a data transmission failure alarm shown on pc. as per sir instruction we have reset master plc but winders were not triped and alarm gone. so what master plc do?
what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration
Q1]IF THE RANGE FOR FLOW IS -35 TO 125 WHAT WILL BE THE SPAN FOR ABSOLUTE AND FOR NORMAL? Q2]HOW TO CALIBRATE CAPILLARY TYPE LT? Q3]HOW MANY ERROR CALCULATIONS ARE THERE USED IN PROCESS INDUSTRIES? Q4]HOW TO CALIBRATE TEMPERATURE TRANSMITTER? Q5] HOW TO CALIBRATE LEVEL TROLL AND HOW TO CONNECT? Q6]PLEASE TELL ME THE BASIC FOR INSTRUMENTATION WHICH IS APPLIED FOR CALIBRATION AND FOR ALL? PLEASE MAIL THE ANSWER TO honest_yes@yahoo.in
how to calculate signal cable sizing? and multipair cable sizing??explain in brief?
why any measurement made interms of pressure is more accurate ? to be more precise most of the flow velocity is made interms of pressure and it is accurate. what is the reason behind pressure measurement being accurate ?
how do u calibrate the vacuum transmitter if it shows more reading
what is function of sensor, and how is it work , explain with difination
I will attend an interview with GasGas company for a position of Instrument Technician ( Offshore )in next month can anyone tell me what questions they will ask. Thanks in advance.
A flange is used for instrument connection for a system with a design temperature of 316C (600F) and a design pressure of 1000 kPa (145 psi). What is the class rating of the flange to be used for this application? Explain your answer
Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .
how can leve transmetter calibate in feild .and also put cv and flow plz .....
why we use the ac supply load cell>?can we use the dc supply load cell?advantages and disadvantage of the ac supply load cell?
Define the terms Accuracy, precission, Spam, process tolerance while doing calibration of an instrument? Explaini with an example?