Answer Posted / viji
computerizing the electric utility
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
How to calculate of maximum demand if given 628kw, 785kva, 0.8 p.f.
in non technical way how can u define POWER FACTOR??
why EMF IS INDUCED IN A CONDUCTOR WHEN FLUX LINKING WITH IT CHANGES ACCORDING TO FARADAYS LAW.
Why the output of OP-AMP is always less than Vcc?
How to calculate the sag of OPGW during stringing???
Why the earth to phase voltage is high 250 compare to other two phases
explain single phase series motor
what is the circulate the diesel in DG in side pls tell parts name and picture with circulate the diesel
What are approaches to tackle sedimentation problem of reservoir?
Single line diagram for dbb (double bus bar)system.
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
Why reactive power is needed in a power system? How is it being absorbed or delivered by alternators? For reactive power control we are changing excitation but reactive power absorbing or delivering related to stator. How these two are interlinked? i want a detailed explanation with necessary expressions and figures?
What does Bode plot tell you?
1.What is captive power plant? 2.What is national grid?Give brief idea.
why impudance relay used for medium transmission power system? why not others?