if HP LP Bypass opened in running condition then what happen
in 210 MW thermal plant
Answer Posted / k. v. vidyanandan
Consequences will be different with different loading conditions of the unit.
Whenever HPBP opens, immediately LP bypass will also open due to the increase in HRH pressure. This may lead to a reduction in condenser vacuum (i.e. increase in condenser pressure). If the condenser pressure goes beyond the set value, turbine will trip on Low Vacuum Protection. This may possibly happen if the unit was running at full load.
If HP BP opens at part load, still LP BP will open, however, chances of vacuum crossing the safe limit is less and therefore unit may survive. But, due to the opening of HP BP, MS pressure will fall, load will reduce and there will be drop in drum level. Operator will get adequate time to take corrective action in this case.
| Is This Answer Correct ? | 11 Yes | 0 No |
Post New Answer View All Answers
Any one please sent me a mahindra tractors model question papers.
what r the advantages and disadvantages of gas burners and oil one?
At 50 Centigrade (Fuel oil) what is its cast?
Temperature closer for brazing operation is-------
Explain why do the radiators in your house click when you start the heating system?
What happen when too much cylinder oil is injected in the working cylinder?
why we r recommended for pre-action sprinklers @ generator/tx/mv panel room. If any leakage there,that panel will damage. So what is the Logic for pre-action sprinklers there?
how to calculate cooling water require to condense x amount of vapor in a condenser.
what is line balancing
What causes damage to impellers?
. What is a magnetic valve of refrigeration system?
What is the most important thing you have achieved as an engineer?
What is the world's hardest metal?
What are your significant functional achievements in the present company? How did they contribute to the total process
What is caustic embrittlement ?