WHAT IS THE DIFFERENCE BETWEEN A TRANSMITTER & A SMART
TRANSMITTER.
Answer Posted / dollary
smart transmitter can used without using hart communicator
unlike ordinary smart transmitter you nee hart communicatot
to configure each parameter that you are going to change or
revised.
Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
typical loop drawing of a simple feedback control comprising of one transmitter and one control
when placing a vent or drain hole on an orifice plate should you measure from the center of the bore up or down for the vent placement?
i have done DAE in Instrumentation and Process Control. i have applied for an apprentice training in chemical company after three day my interview will be conduct but i need more information about industrial process control and controller. my e mail is imran_dilsetu@yahoo.com please tell me interview question relative to instrumentation ?
How many interlocks at turbine side?
I faced several time siemens ps2 positioner automatically getting Chang in it's set point direction after auto calibration So is there any causes biside this or any permissives ?
Can anyone convert a 5/2 way or 3/2 way valve into an ISO valve?
Lux meter is the measuring device to measure the lux level of lighting fixture. in industrial sector two types of lighting fixture is being used as street lighting purpose 1. HPSV (Sodium) and 2. HPMV (Mercury). HPMV having white light which is an combination of red, blue and yellow colour, while HPSV haivng Yellow lighting. in HPSV red & blue colour will be absent. during measurement of the lux level of HPSV and HPMV fixture. 1. Lux meter can measure the actual lux level of both fixture? 2. or it will show false reading for HPSV fixture light as it has only yellow light present. please give me answer
what is the field bus calble ? what are diffrences in orang colur cable and black coular calble ?
What is intrinsically safe system?
A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.
in differential pressure transmitter,min&max pressure range for hp&lp
, Instrument Index, P&ID review, I/O schedule, datasheet, DCS / Analyzers specifications, loop diagrams, hook-up drawings.
how to relay switch sense the fault?
Differentiate between ultrasonic flowmeter and radar type flow meter
what is different between 2,3&4 wire rtd and how much maximum distance using plc to field.