Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is phase angle? and what is importance to measure it?

Answer Posted / @vi

Phase angle is the phasor angle between the voltage and
current. It is very important which determines the real
power delivered to the load..

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

if i am in front of transmission line how to know that current direction without any equipment

1837


neutral earth resistance testing is it possible for transformer while in load condition

2013


How to arrange a hous hold earthing system to keep minimum earth resistance( below 7ohms).

2217


What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB

1650


How does cost of generation from hydropower plant compare with other sources of electricity?

1111


If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?

2362


what is the effect of connecting three phase supply lines to three phase auto transformer output terminals through a fuse of 10Amp and a circuit breaker (MCB). Is this connection permanently destroy the transformer?

1982


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2272


specific difference of ICT&Auto Transformer

1947


What are the functions of temperature scanner in power transformer?

2231


Compare salient pole and cylindrical rotor machines.

1931


earth also having a gravitational force (magnetic field of north and south)but it attracts any object compare to this theartifical magnetic cant perform same as earth why?

2027


why use phase displacement in transformer.and effect of phase displacement on transformer

2913


what is earth pit , how we can measured it, what earth rods reference

2659


I want to design a heating coil of 80/20 nicrome for 3.5KW please give me the calculations choosing for physical dimensions assume coil voltage will be 110V AC assume necessary conditions

1654