Boiler capacity is 5ton, what will be the feed water tank
capacity?
Answer Posted / pradeepkumar
1000Gallons of water
| Is This Answer Correct ? | 1 Yes | 4 No |
Post New Answer View All Answers
LAPT working in alternator / generator
What is LB-SR.
why is the in steam turbine axial displacement of active side thrust pad is positive and non active side thrust pad is negative.
How to calculate boiler capacity? I have 1 Autoclave, Which has to use for AAC block. Dimension for this Autoclave is - 13 Meter Length & 2.2 Meter Diameter.
By any way can we increase the B check hours from 300 to 500
DCS marshaling Cabinet Power supply can be replace during plant running time? Answer Yes it is possible. I am talking about the controller and cards power supply modules. They are always redundant and connected through diode so that if one power supply fails the other can take the charge immediately.so it is possible to replace one of them in running plant if the other one is healthy. MY question is how switching done.
Qatar Fertiliser Company (QAFCO) Shortlisted me for interview (got the intel from my source) for Field Operator- Utilities post. Please let me know what kind of questions they asked? ... this position requires 5 years of experience in Power Plant and background Diploma in Electrical/ Mech. ... my Background is Electrical and I am a sub Assistant Engineer (Operation) at a private HFO based Power plant... PS: Please Let me know what preparation should I take to obtain the Interview which will be take place In Bangladesh soon
explain how the third harmonic content of the magnetising current affects transformer design
what does mean by kva rating
What is surging in a centrifugal compressor ? How it occur's ? How is antisurging done ?
Why superheated are started before I'd and rd fan?
can dp type level transmitter work in under vaccum condition
procedure of how to generate power in solar plant.
We have Demin Closed cooling water system with expansion tank for cooling oil system. Expansion tank having N2 bladder. Whenever N2 bladder bursts out, Closed cooling water circuit pressure drops and make-up happening, eventhough there is no leaks. And how Circuit pressure drops?
what's the moog valve