Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why we use mostly circular coil in transformer? not square or
rectangular type of coil.

Answer Posted / deepak24

for a definite area of core a circle has smallest circumference. so circle has smallest mean length of copper. so cost will reduce for copper for circular winding.

Is This Answer Correct ?    13 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks

1756


How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?

1065


is ac supply can store

2095


what is the most permissible winding temp when we conducting a generator load test?(condition no load)

1710


why on axial hitting up of air blast on hydrogen produced in oil circuit breaker,temperature rises of the core of the arc?

1955


how could we know the size of cable by physical view?

1614


What is the physical significance of phase.. i.e. what is exactly the meaning in layman's language.. 1 phase, 3 phase etc ???

2163


if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .

1657


What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?

3727


Why lose 1 phase voltage in 33kv to 415v stepdown transformer

1731


Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?

1819


describe the A.C. Generator Testing procedure

2166


what is the difference b/w UHVDC and HVDC(LIGHT)?

6738


How to check the cable fault / hv test of transformer cable.

1872


What are stable systems?

1077