Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if i have one capacitor=80 micro farad which correct the unity
power factor,but i want to make capacitor bank who correct the
power factor.so,how to split this capacitance value?

Answer Posted / mohammad anas

if the connection is 440 valt , and the power factor increses , then what is the value of capacitor used in this circuit?

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to compare with Relay settings for HT< panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps

1261


66kv under ground cable how to layaing in ground any special case two ckt r runing

1996


What's mean HVF & HAF in Vacuum Circuit Breaker?

5350


If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?

2311


Why the efficiency of generator is more than motor in swinburne's test

2022


what is the power rating of CPU, CRT type moniter, LCD type moniter,scanner Approx.

2200


how to select proper cable for ct wiring so that drop within the limit.

1974


specific difference of ICT&Auto Transformer

1897


magnetizer priciple

2093


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1658


XYZ

2143


explain the functions of main isolation switches

1680


What is referred to the electron in the outer orbit?

1158


Which material is used for the core of a transformer and why?

1107


What is the basic principle of operation of alternators/dc generators?

1104