wat s reactive power.... how could it be compensated.....

Answer Posted / mukesh kumar

There are Three Types of power 1)Active Power 2)Reactive
Power 3)Apperent Power
*Active Power or True Power is used by Equ.to do actual
work Like-Rotation of Motor,Voltage generation of Generator
etc.

*Reactive power is imaginary power which is used by Equ.to
get Magnetised their winding ,sothat Equ. can do their
actual work.
It can be Compensated by Capacitor Bank,SYnchronous
Condenser ,By increasing of Excitation of Alternator.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is Electrical Grade Aluminum for Tubular BusBars. i am confused between 6063 and T6 or T5 and what is BS 2898 and BS 159?

1428


explain Density

656


Can Anyone suggest the Standards (IEC or IS) for selecting copper current density?

923


Name the test signals used in control system

807


Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend

1514






What are the advantages of speed control using thyristor?

656


(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)

1424


In the formula : Knee point voltage = Burden X alf / class, Please inform what is alf? regards Shashidhar M.R.

3400


how can motor both beasrings insulation resistance can be check?

1559


What is touch potential and step potential?

1631


How the over load setting for HT Motors calculated-provided in Numerical Relay

1206


Salient pole alternator is more stable, why?

2086


A 1F capacitor is charged to 100V initially. A 1H inductor is connected accros the capacitor througha a switch. The current in the circiut when the switch is closed is____

1879


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1258


testing of Vector Group – YNaoD II

2464