For an 100kw generator, only 50kw of load is connected.
will the generator generate only 50kw or 100kw. if it
generate 100kw what happens to rest of the 50kw. what
happens if we connect more than 100kw of load?

Answer Posted / erharisheee51

First one thing understand clearly.Generator Generates only
voltage say 11kV for ex .. so it will convert to power its
depends on the load. so if the Load increases automatically
generator terminal voltage will go down & Frequency (speed)
.so you have to increase the excitation voltage to maintain
the terminal voltage normal , if the load is less u can
reduce the excitation no need of wasting external power
(excitation voltage) also.
so i guess if the load is low r high..there is no change in
generator generation it will generate the fixed voltage ..

and the Bill will maintained only usage not generation so i
if they used 50 kw they will charge for the same , remaining
50 kw u have saved.thats it..

Please leave a commnent for this :)

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

The capacitive reactance of a capacitor of 1/(2(PI)) F at 10^3 H is

1417


Sir 33kva 2 transformer load 900 amp calc 1800 amp mana jayega

1375


why in the three pin plug all 3 pins are cutted ?

1539


What is frantic effect?

709


Can anyone tell the proper diagram of star delta starter????

1476






I have doubt that the supply HZ (very low or high than rated ) may affect the power factor. is it true. ?

1227


what is mean by dual digital protection in the relay field?

1479


why is a power transformer used only occasionally?it is used to step up at generating stations?and that needs to be done all day long !!!!!!!

1377


What is Load sharing of Transformer ?

1554


Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.

1512


impliment (AB)`+C to transistor representation

1349


1.what is difference between ATS & STS main use. 2.what is difference between ACB& VCB With symobles,and main partes, manimum range. 3.How many types of relays and main function.

5614


which pump used in WTP explain the function of VFD how to dtermine capacitorbank of capacity one plant

1479


we have consol make 3 phase servo stabilizer for cnc m/c. while installing the earth neutral voltage is 1.7 volts at stbilizer off condition and when stabilizer get on en voltage reaches 4.8 volts (new earthing is done and neutral is helthy condition all phase to neutral volts 440,442,441 v)why this happen.solution for cause.

5576


What is Antipumping Function & If we have C.T how we find the Ratio ?

1529