difference between ceiling fan
Answer Posted / rohtash kathwalia
In ceiling fan stator is rotating part and in table fan
rotor is the rotating part. Ceiling Fan Rotate in anti clock-wise direction by bearing and table Fan Rotate in clock-wise direction by bush.
Table Fan-*Rotation is in Anti clock-wise direction
*Used Bushing
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
how to calculate the power factor when instantaneous voltage and current has harmonics in it ?
what is difference between bus coupler and auto transfer switch
What is the comparison of PILC and XLPE cable
what is the relative size of single and three phase?
A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?
how synchronous condenser is used in place of synchronous generator with out negotiating IEEE standards? Can i use 3 generators as synchronous generators and 2 generators as a synchronous condensers in an IEEE 14 bus system with out disturbing the standards?
Can u explain : what is supply for train (whether a,c or d.c ).I know that supply is 25000v a.c .But there is rumour that supply is D.C. And also explain how lights and fans inside the trains are working ,and what type of motors are used in trains whether D.C motors or induction motors .If d.c motor, how it gets supply.If traction motors are used then what are traction motors and its functions and how it differs from other motors and also explain about locomotive . y d.c series motor in train.train wheels r driven by D.C shunt motor ,at what voltage,and at what speed. please reply..............
An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.
The D.C. spark test is applicable to single conductor cable & assemblies of insulated single conductor cables without insulation shield,metallic sheath or metalic armor?
what is formula for zero phase sequence of nuetal earthing transformer of 6.6 kv
why we testing the core balance of the transformer before comissioning?
How cable from Kit-Kat to main switch, from starter to motor are designed?
How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.
What will be the output voltage of a transformer if it is primarily energized from a square wave voltage source?
what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.