pf of synchronius motor is unity, is it axact(=one) value. ?
Answer Posted / sidharth
It depends on condition in which you are operating it.
If you are operating it over excited and on no load condition then its power factor is greater than 1(this is used to used to improve power factor).
If it is operating in under excited condition then power factor is less than 1.(it will supply reactive power).
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
What is the function of attenuator in cro?
we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer
please send previous exams question papers
Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?
What is core CT & it's function?
why do we use spark detector inside the slip ring brush compartment 0ona slip ring induction motor?
Which motor connection is preferable star-delta or delta-star?
how to build a network which step down 415v to 1v rms
In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.
some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
what is the thumb rule for determination resistance of resistor?
What is Harmonics how it is produced and what is the method to control the same
WHAT IS MOBILE SUB-STATION? & REALLY BENEFIT IN INDIA
What range of speed can you get with the armature control method of speed control of d.c. Shunt motor?