Answer Posted / ashok mishra
the correct answer is current
because miliampere current is efficient to make the shock in our body
current produces I2R losses means heat
and after getting shock our body burns
. . .voltage is the reference name of current it just make it to flow
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
Why neutral cable carry current.
1.4 What is meant by CT knee point voltage and how would you determine it
hi , i have 150 kw loud and we need 50 m cabil,i want to know wich size cabil we use. thanks
A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
what is meant by directional earth fault and non directional earth fault? describe both.
ii) A shunt motor supplied at 230V, runs at 900 rpm when the current is 30A. The resistance of the armature is 0.4 ohms. Calculate the resistance required in series with the armature to reduce the speed to 600 rpm, assuming that the armature current is then 20A. [12]
It is desired to flood light the front of a building 42 meters wide and 16 meters hig.Projectors of 30 degree beam spread and 1000 watt lamps giving 20 lumen/watt are availabl.If the desired level of illumination is 75 lumen/m and show a suitable scheme.Assume the cofficient of utilization, deprecitation factor and waste light factor are 0.4, 13 and 1.2 respectively.
Why the efficiency of generator is more than motor in swinburne's test
What is kirchoff ’s current law (kcl)?
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
hi frnds...pls send me aptransco previous papers .....pls..pls,,,(madhar.rocking@gmail.com)and suggest me some websites
what is diff btw electric,magnetic & eletromagnetic field
why they were using TRIAC instead relay in some controllers and what is the advantages.
what do you mean by every IC 74 first digit.why are you using this no.why not using another no.