Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to decided test concentration in GC analysis.

Answer Posted / chennusrinivas

The concentration of GC sample depends on interest solvent PPE
limits .

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3726


What is Band broading effect explain

1941


how you establish the LOQ?

843


What is the difference between purge septum flow and column flow in gas chromatography?

2648


Identify problem faced when mass spectroscopy is used with HPLC system ?

1932


what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?

4537


How would you decide dissolution medium for NCE compound of class I drug

2314


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

820


how to set sample and standard concentration in RS method?

967


we are performed SOR for a particular product the limit is -6 to -10.We face particular bathes it is not meeting the specification.we performed diffrent instrument diffrent analyst we are getting diffrent diffrent results.solvent is dimethyl sulfoxide what could be the reasion

1921


which one is better separation in high pressure liquide chromatogram orlowpressure chromato gram in hplc

2214


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2746


in hplc chromatogram started from left to right and in uv spectrum started from left to right

1016


Why acetonitrile and water are used as extraction solvent when analysis melamine? I thought they are miscible and won't be able to separate...

1752


What is related substance by HPLC impurity limits as per USP?

1158