why the voltage transmission is always in a multiple of 11?
e.g. 110 V, 220 V, 33 kVA, 11 kVA
Answer Posted / lucky dhiman
becoz the form
factor for a.c sine
wave is 1.11 so
transmission
voltage will always
bi multiple of
11. . . . . .
| Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
Showing results for capital, machinery, stock,wages, carriage in words, salaries, factory rent, repairs, fuel and power, buildings, debtors, sales, purchases, creditors, return outwords, return inwords, drawings, discount allowed, discount receivable, office expenses, bills payable, bills receivable, cash in hand, cash at bank, office rent comes under debit or credit
How good are you in resolving the commercial issues to Employer's advantage?
How to test Alternator stability test for REF relay
What is a surge supressor why its is used in synchronous generators
how synchronous condenser is used in place of synchronous generator with out negotiating IEEE standards? Can i use 3 generators as synchronous generators and 2 generators as a synchronous condensers in an IEEE 14 bus system with out disturbing the standards?
1.What will be stored in online ups EPROM IC?
What would cause a 240v choke that should give 110v out on a 16w lamp to gradually increase to 160v?
In EDO ACBs what is a purpose of closing coil and motor, what is the operation of these devices are they inetconnected. means if we give supply to motor and by BCS we charge Closing coil,what exact is operation is and how it charge a spring of ACB. Sir if anybody has an wiring diagram please send me the link to operate and EDO breaker.
Which type of air compressor is used now a days in the market. Keeping in mind of energy efficiency and maintenance points. Relevant documents may also be sent on mentioned email ids.
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
we all know voltage is a force(emf), and the force always devides if 2 or more than2 loads are there but why does the voltage remains same is parallel, it must devide na ???
Is any generator is developed which is operated with out diesal or other expensive source?
how many joints are allowed in underground HT cable of 1 KM
what are the condition that makes hooter blow?
Differenciate between circuit wiring and sub main wiring with illustrations