can we run 3 phase induction motor under 2 phase supply
Answer Posted / engineer bhai
yes we can run induction motor on 2 phase supply there are
three methods
1. first rotate the roter with some externel means and in
running condition of the motor switch on the supply.motor
will start running but in unbalanced and unstable condition.
2. connect a capacitor to one of the phase and give supply
to the motor with two already awailable phases and one with
the capacitor.capacitor will provide required phase
dispacement.motor will be more stable in this connection.
3. use scot connection of transformer to provide 3 phase
supply.
| Is This Answer Correct ? | 34 Yes | 6 No |
Post New Answer View All Answers
why should the lowest unit of a testing transformer ( cascaded transformer ) have higher power rating??
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
Mention what are the different colors on wires indicates?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
what is the use of Auto re-closer?
does buccholz in a transformer use batteries
List the characteristics of filter?
Grid fault level [KA]?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
how do u gauge the size of the cable ?for eg. consider a 300 sqmm L.T Cable.How do u determine the size of the cable seeing it pratically?
why electronic instruments is more favorable than electrical?
sir, I am from EEE branch.On feb 17 iam going to write an Exam for hindustan petrolium corporation Ltd.So plz send me the written exam pattern/Q's/interview questions.please mail to eee_dharmendra@yahoo.com
how to calculate transformer turn primary & secondary side 11kv to 420v
What is the size of a 60 watt and 80 watt tubelight?
how to calculate units consumption for a 12 hp motor /hr.