Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the column performance and column efficiency?

Answer Posted / kishor solanke

column performance is the column should comply the stated
systemsuitability in case of dedication OR It may satisfies
the common general criterian used for all column while
receiving new column OR Check the performance as per
manufacturer recommendations.
Column Effecience: This is regarding to the therotical
plates which results in the peak sharpness as more the peak
sharp more its 'N' no. of therotial plates as more
efficient column.

Is This Answer Correct ?    27 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3631


Loss of linearity in tkn analysis, possible reasons?

1285


IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?

2425


which situation gc hs and gc als require to use?

747


how to select short coloum and long coloumn for new molecule

2391


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2734


what is turbidimetric titration?Give 2 examples.

2614


What is viod volume and peak purity in HPLC?

2835


What is related substance by HPLC impurity limits as per USP?

1061


What is stray light in uv what are units for stray light

1590


Ph meter can show more than 14 ph reading? Why ph range in between 1 to 14 only?

713


2. Two grams of Benzoic acid are dissolved in 200 ml of water and extracted with 200 ml of diethyl ether. The distribution coefficient of benzoic acid is 100, and its dissociation constant is 6.5 10-5. Calculate the distribution ratio (D) of benzoic acid at pH 2, 5, and 6. 3. Calculate D at pH 2 to 10 (1 unit apart) in the above problem, and plot D versus pH.

2183


Why we select scan range from higer wavelength to lower wavelength in uv visible spectroscopy and ftir spectroscopy ? .

883


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2197


what you do when compound having dwel wavelength?

722