Answer Posted / *avi
Flux means nothing but some kind of line of force. Whenever
current flows through magnetic field causes the flux
production around that conductor.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
what is errection pcbs?
what is meaning of bus riser
What is the use of lag compensator?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
why the value of k is more in shell typr transformers?
what is the difference between gas group b and gas group c electrical equipment construction wise?
why we are not giving the zone 1 trip command to the master trip relay
WHAT IS THE WINDING PROCEDURE OF ELECTRICAL MOTOR
what is the difference between interconnection and intraconnections in the circuit diagrams
Dear all, how we select the cable size according to current with or without including different correction factor , is there any direct method for sizing of cable...
1.why we are using metal oxide gapless block in lightning arrester,2.What is minimum and maximum rating of metal oxide blocks using in india
Define settling time.
Why an ac solenoid valve attract the plunger even though we interchanges the terminal? Will the poles changes?
WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?
in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain