Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the diff b/n OVI and Residual solvents

Answer Posted / 2020analytical

OVI terminology is used by USP-NF upto last revision
USP29-NF24 after that USP also Use Residual solvents
terminology.

Is This Answer Correct ?    12 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

873


What is split ratio in Gc? Splitless? how requirr to select?

847


Why do we use KMnO4 in the test of control of obsorbance ? and why do we take specific quantity i.e 57-63mg?

2793


when we talk about change in entropy we consider total entropy means of surround +entropy of system but when we talk about change in Gibss free energy we consider entropy of system.explain with reason.

2008


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1943


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1290


Is it nessesary all multimedia dissolution require descriminatory?

762


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

1577


what is the difference between potentiometric titration and karl fischer titration?

3141


IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?

2425


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

886


How doing qbd practically?

933


Difference between hlaf and rlaf

2077


all types of questions asked at the cipla interview

4650


if you have given one product then how you determine the impurity in that?

708