why hv current transformers have big size ?
Answer Posted / twinkle
high voltage means more number of turn and consequently large size
| Is This Answer Correct ? | 4 Yes | 0 No |
Post New Answer View All Answers
why booster transformer is used in sumpners test conducted on transformer????
how unidirectional torque is produced in DC motor?
i need some project topics along with circuit diagram in the electrical adnd electronics engg and also give ome website regarding projects.my mail id is thenmozhi2k7@gmail.com .please help me.
What will happen if i replace a inductive proximity switch with photo sensor in a machine?
We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's
why swityard is necessrry requirement in any bis power distributin systems?
5.WHICH TYPE WELDING PROCESSES USES NON CONSUMABLE ELECTRODE.........
hai now i am working as a electrical design engineer in construction field can i get a job in oil and gass field or power plant project as a electrical design engineer?
Define resonant frequency?
what is the purpose of silicon dropper used in battery charger?
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
What are chief characteristics of state-space method and its techniques ?
what is the function of choke in the flourcent tube lights and why the colour is in white mostly in flourcent tube lights
in shunt clippers why a resistor is used in sereis with the input
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?