Answer Posted / sagar
Ohm's law only applicable to purely resistive circuit in which v --> I relationship is linear.
now in the case of the transformer , there is reactance is exist and there is induction also.It's not purely resistive circuit and v --> I relationship is non-linear.so ohm's law is not applicable to transformer
| Is This Answer Correct ? | 2 Yes | 1 No |
Post New Answer View All Answers
What type of pipe material G.I or M.S is used for sprinkler system?
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.
Difference between control junction box (cjb) and power junction box(pjb)?
Hi Friend I am used multimeter to measure the voltage between R Phase(SS1) to R Phase(SS2). In SS1 is connected with UPS loads. But I am getting voltage between these 2 R Phases. Please give some idea friend
How cable from Kit-Kat to main switch, from starter to motor are designed?
Name the component u would expect to find in a switchgear assembly?
Why we are using Isolation Power Transformer inplace of commercial power transformer? What's the difference between them?
how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
why u r living from presentaly working.
Is it a better option to procure screw type air compressor rather than reciprocating air compressor?If so, what is the reason?How should we select an air compressor(100 CFM)? Please mention the important parameters of air compressor.
in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses? the second question is-generation is depends on LV winding? or LV winding design for generation voltage?
What is K-rated transformer? What is the use of it? What can be the size(pls provide calculation if possible) of K- factor transformer for 550kW,690V motor operating with drive (VFD)?
Difference between shunt, PMG and AREP excitation. Which is the most reliable between PMG and AREP.
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?