Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if dc is better then ac...then why we are perfering ac over
dc?eg:at home?

Answer Posted / najeeb

AC can easily be stepped up or stepped down. specially for
transmission we must have high voltages in order to have
low losses,
while stepping up or stepping down dc is very complex and
expensive.
this is the main feature that we consider,
while of course dc is better as dc resistance is lower than
ac resistance,no reactance and power factor problems,

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

2045


why we get 2 differnet values for power factor in 2 watt meter method in 3 phase

1916


Instrument connected to a single phase supply

1748


Why Stabilising Resistor used in REF circuit ?

3395


A 11KV, 1200 A breaker combination fixed in a cubicle for HT motor.Is normally for 11 KV motor fuse is using? if Yes, What range fuse is required?

2026


Dear Mr B C pal...Can you plz. put some light on principle of operation of Z-Ct in conjunction to its use with 1Cx1000Sqmm HT Cables & Directional Ground Fault / Over Voltage Relays...Regd..Parag v K 9899115632

2814


Following test should be conducted to find out relative polarity of transformenr terminals A no load test B back to back test C phasing out test D none of above

2272


What is resonant frequency?

1342


HOW CAN YOU CALCULATE PRACTICAL EFFICIENCY OF A ASYNCHRONOUS INDUCTIONMOTOR OF 7.5KW,& MOTOR IS RUNNING WITH AVOLTAGE OF 410 VOLTS,& TAKING CURENT OF 13 AMPS

1940


What is the Minimum winding resistance of motors ( small & big)? referance range

2367


Give two basic speed control scheme of dc shunt motor?

1153


explain working principle of earth leakage relay

3763


How to calculate main incomer rating of APFC Panel ? Let's say i want to find main incomer for 11kV, 1000kVAR Panel.

2024


Is there any rule to select the voltage of motor based on KW rating? What is the rating above which lt motor becomes the HT motor?.

1784


What is the types of HT motor testing

3655