Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is post run in hplc?

Answer Posted / satheesh kumar

Post run in hplc comes under the gradient programme
(Gradient elution).

Gradient Programme-:

Time(min) A% B%(Where-A% Buffer,B%-ACN)

0.01 80 20
10.00 50 50
25.00 20 80
30.00 20 80
35.00 80 20
45.00 80 20

In the above gradient Intially starts with Buffer,ACN in
one proportion,when the time incerases proportion changed
and finallty returns to original proportion is called Post
run or equilibrqtion time

Is This Answer Correct ?    13 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Please give idea about method development for cleaning method and how maco level establish

788


if identification threshold crosses the limits then what next step?

915


how you start RS method development when for new product?

774


For limit test of heavy metals in BP, Method C require that the substance is ignited at a temperature not exceeding 800 °C. Why confines such the temperature?

4130


if your impurity coeluting with each other in that situation how require to set specification? is it acceptable?

1042


How to do regeneration of Metacarb Pb plus column?

2610


how to develop the icp ms method? Application of icp ms?

845


Tell me something about Vitamin A test method by HPLC

2722


from where i get mortar pastle for glass bottle crush? it's required for testing of it?

2328


What is the Formula for coreletion coefficient in plhplc calibration

1880


Why only Copper standard is used to calibrate Atomic Absorption spectrophotometer?

2783


Which parameter require to do for analytical method equivalency?

817


how to decide for one product require water content or LOD?

835


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

974


Why sodium hydroxide used for maintain pH of phosphate buffer

2481