What the capacitor Current formula?, For 1 KVAr how amps
its required? for using the KVAr for boosting the PF Design
Calculation.( Eg: for 30 KVAr required how many KW?)
Answer Posted / 9561354591
** Capacitor Current formula is
I= kVAr/kV/1.732 ( for 3 ph capacitor )
**for 1 kVar capacitor... suppose voltage is 440 volts than,
I=1/0.440/1.732
I=1.31 Amps.
For all your information,generally 1 kVAr capacitor takes
0.5 watts...henceforth..
30 kvar capacitor required kw=30X0.5=15 watts and is 0.015kw
thanks!!!!!!!
| Is This Answer Correct ? | 23 Yes | 14 No |
Post New Answer View All Answers
why ups rating in kva? and why ups are in parellel?.why isolation transformer is used in ups?
What is the difference between security constraint unit commitment and security constraint optimal power flow?
how did the testing of protection relays done through current injection
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
why single phase to grd test in HV cable?why not 2 phase at a time?
what is method for testing CT
what is under coal gassification?
what is the efficiency of thyristor
When lag/lead/lag-lead compensation is employed?
can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?
I NEED RRB APTITUDE QUESTIONS AND MODEL PAPER,PLEASE SEND MY E-MAIL joo28_eee@yahoo.co.in
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.
How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?