How can we select a capacitor Bank.? i need a standard
formula for that.?

Answer Posted / asif

kvar = kw(tanø1 - tanø2)

where ø2 is the existing power factor and

ø1 is the desired power factor.

Is This Answer Correct ?    10 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

CPC cable .PVC \1C....I want to get sure that type is flexible indoor or to be install on trench. please advice .thanx :)

1424


HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????

1698


WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION

1501


why we change the direction of winding in rotor ?how we make the north and south pole?

1592


what is fault level of power system ?

5109






What is the working mechanism of OLTC in Power Transformers????

3892


how can i change the rotation of the AC single phase induction motor and show me by diagram

1316


How to calculate the input cable rating for 10kva ups (3phase input and single phase output and also 3phase output, battery rating 65Ah)provide the formula also.thnx

1779


need to make a report. Need to choose a 3phase induction motor. Load conditions motor will operate in : Maximum Load: 30 Kw Speed: 2950 rpm Ambient temp: 20 cent Supply voltage: 440V Frequency: 50Hz need to look for the safety factor when choosing the motor, went through catalouge found a few, but dont know how to choose the safety factor allowing an extra load something above 30 KW to avoid any harm.

1317


What is the difference between a verilog task and a verilog function?

674


How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend

1629


Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel

1533


Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.

1598


What is the difference between line drop and percentage line drop?

1079


why transformer tank is in rectangular shape what happen when it is in step shape

958