1)Why electric shock is feel ?? n in a Electric Train why
we didnt feel that ?

2)What is the reason for transformer Noise ??

3)What is relation b/w Transmission Lines & Communication
Lines ?

4)Which material is used for making Transformer oil & How u
measure its dielectric strength & Name the test ?





Answer Posted / arjun chaudhary

Ans 2) magnetostriction (when there is changing magnetic
field due to alternating current vibration occurs due to
which sound comes at full load ) eg. we use two black
magnets (two magnets so same length and effect) when we
throw in air we get the hissing sound because of changing
magnetic field .

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to Calculate The sag of OPGW in Transmission Line???

2672


how to calculate current carring capacity of cable and cable selection? 1) copper flexible cable 2) copper armoured cable 3) Aluminium cable

1063


What should be the height of basement according to NBCC code?

1727


we are going to install a solar PV site and how can we calculate PV Solar Panel Efficiency, can anybody tell me complete method for its calculation.

1582


what is the function of capacitor duty contactor in an capacitor panel???

3632






what is rocking arrangement in arc heating

1689


where lt & ht capacitor used

1767


How to choose size of the cable w.r.to current carrying capacity ...

1692


i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test

1386


I have 4 busbar of 1000 ampere. we use 4 busbar to make 4000 ampere in one phase.my problem is that when we applied 60% load on that then busbar produced high noise.what is the reason of that and how can i minimize that noise.

1299


Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?

1480


if a number of plc s are there then how many modbus to be used

1549


if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .

1166


Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing

1471


1)we have 1000 cfm Blower,Dia-1Mtr,Velocity of air 94 m/s 2)We have Natural Air velocity 94m/s 3If i Put Wind Mill in natural air ,speed is 94m/s Then it will generate Assume 100kw 4)If i put same wind mill across the Blower,air speed is same 94m/s now the Question is Will it generate 100 kw?

1521