1)Why electric shock is feel ?? n in a Electric Train why
we didnt feel that ?
2)What is the reason for transformer Noise ??
3)What is relation b/w Transmission Lines & Communication
Lines ?
4)Which material is used for making Transformer oil & How u
measure its dielectric strength & Name the test ?
Answer Posted / arjun chaudhary
Ans 2) magnetostriction (when there is changing magnetic
field due to alternating current vibration occurs due to
which sound comes at full load ) eg. we use two black
magnets (two magnets so same length and effect) when we
throw in air we get the hissing sound because of changing
magnetic field .
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
How to Calculate The sag of OPGW in Transmission Line???
how to calculate current carring capacity of cable and cable selection? 1) copper flexible cable 2) copper armoured cable 3) Aluminium cable
What should be the height of basement according to NBCC code?
we are going to install a solar PV site and how can we calculate PV Solar Panel Efficiency, can anybody tell me complete method for its calculation.
what is the function of capacitor duty contactor in an capacitor panel???
what is rocking arrangement in arc heating
where lt & ht capacitor used
How to choose size of the cable w.r.to current carrying capacity ...
i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test
I have 4 busbar of 1000 ampere. we use 4 busbar to make 4000 ampere in one phase.my problem is that when we applied 60% load on that then busbar produced high noise.what is the reason of that and how can i minimize that noise.
Is it acceptable of installing an earth pit in planters area where bare copper cable, earth rod and connection are susceptible to corrosion due to water?
if a number of plc s are there then how many modbus to be used
if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .
Installation resistance for whole installation of 16 kva & 25 KVA DTRA a) Between each conductor b) between conductor to earth c) installation resistance for each apparatus, each conductor to earth d) earth resistance for the system of earthing
1)we have 1000 cfm Blower,Dia-1Mtr,Velocity of air 94 m/s 2)We have Natural Air velocity 94m/s 3If i Put Wind Mill in natural air ,speed is 94m/s Then it will generate Assume 100kw 4)If i put same wind mill across the Blower,air speed is same 94m/s now the Question is Will it generate 100 kw?