Answer Posted / bala murali
By using DP txr for Calculation of Flow we are enable squre
root in Txr.
This is bcoz the flow is directly proportional to square
root of Diff. pressure b/w HP and LP.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is zone,loop/fire alarm system?
what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.
i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com
what is SIL 1 2 3
what is the minimum power (P=VI)to produce a spark?
What is the formula of vabration sesore. i mean how to covert mils to volt plz share if any body knows very argent : my mai is merajalam143545@yahoo.com
selection of the zener barrier for the hazardeous area zone 0
which processor is used in dcs.
what is droop in governer ,type of droop ,how it work
i hav applied for the post of engg. in iocl so please require the past test papers fro instrumentation engg please please help me and send me the papers or tell me the pattern and type of ques asked in examination......
Make a ladder diagram on LSL valve will close, on PSL valve will open and start the motor
need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
Any one can help me to identified, how can we interchange the device in FF
Conversions