Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why triethylamine and o-phosphoric acid used while setting
pH of mobile phase during HPLC Analysis?

Answer Posted / venugopal

These are weak acid and weak base compared to
HCl,sulphuric acid, NaOH.Generally the salts used in
preparing the buffers are sodium phosphate/potassium
phosphate.Hence these reagents are added.

Is This Answer Correct ?    9 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How would you decide dissolution medium for NCE compound of class I drug

2244


Why irmoisture balance is used for corrugated box moisture testing

2398


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

2757


Qc interview questions

1733


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

906


what is mean by ambient temperature?

910


how to get accurate result for Residue on evaporation in purified water

1638


WHAT IS THE PURPOSE WE USE HCL, CHOPPER, BURNER, MONOCHROMATOR in AAS? PLEASE EXPLAIN BRIEFLY

2601


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1964


How do we fix the sample concentaryion in hplc method development?

1128


Why dissolution test is not performed in all of the products

2529


what is difference in ods I ods II is this is realy from sorbent / packing characteristics or from other means

1960


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

767


Difference between the quantitative analysis and qualitative analysis?

1159


in DMF having extra impurities and in api COA also having extra imp than USP or BP product then how require to proceed?

820