Answer Posted / bhavik .j.sudra
tranmitters or transmitter.....????????????
transmitter means non -electricalsignal is converted into
equvalent electrical signal.
ans :because it is determind my output devive are which
type we measured air .pressure,flow,level,temp,etc......
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
How would you choose differential range?
what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?
is motorized valve closed when power shutoff?
I want to know the questions asked in ONGC interview(after being selected in the written exam) for Instrumentation branch.Kindly help.
What is force balance principle? State some of its’ advantages.
What do you know about gail?
Where is wet leg is used?
IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?
Explain the working of an enraf level gauge.
what is the reason while warning lamp is on while the engine is cranking?
what is the diffrence between pressure safety valve & pressure relief valve....pls
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?
you are on site,the plant trips,you are approached by operations,what do you do?