Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the T/C & RTD mesuremaint?

Answer Posted / deepak nayak

A thermocouple consists of two conductors of different
materials (usually metal alloys) that produce a voltage in
the vicinity of the point where the two conductors are in
contact. The voltage produced is dependent on, but not
necessarily proportional to, the difference of temperature
of the junction to other parts of those conductors.
resistance temperature detectors (RTDs), are sensors used to
measure temperature by correlating the resistance of the RTD
element with temperature. Most RTD elements consist of a
length of fine coiled wire wrapped around a ceramic or glass
core. The element is usually quite fragile, so it is often
placed inside a sheathed probe to protect it.The material
has a predictable change in resistance as the temperature
changes; it is this predictable change that is used to
determine temperature.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)

2068


HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.

2256


What is Positive Calibration and Negative Calibration?

2240


If we increase only P what will be controller action ?

2459


Im having problems with interfase betwen SPI v7.0 and SPPID v5.05. Previous versions of Intools shoul be fixed with SPPIDproj.ocx file. It was necessary to replace this file with one that allows the connection between different versions of SPPID. It is necessary in the current version to do the same?Thanks

2299


what is the electrical operation procedure for switching on 27.6MVA electric furnace.

2024


Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

2168


how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?

5664


Draw a wheatstone bridge circuit showing supply, meter and 3 wire RTD connection

2007


What is the function of solenoid valve in on/off & shutdown valve and why it is not used in control valve normally?

2011


What is eddy current? Describe the operating principle of proximity probe.

2290


how do we commission inergen system?

1941


KAlman filter code for two dimension?

2056


what is the process for double acting cylinder pneumatic for 32' v/v

2068


please send data bank of quetions answers on analytical instrumentation.

1858