why are set -10vdc in bently neveda vibration system.
Answer Posted / mohd
when the shaft moves toward the probe ,the gap vpltage will
change and that will be reflect on the negative voltage .
the main idea of using -10Vdc is to avoid interfering with
the noise signal which could give error in the reading .
| Is This Answer Correct ? | 8 Yes | 3 No |
Post New Answer View All Answers
tell me the field & lab calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter, temperature transmitter, temperature indicator, flow indicator, level indicator, control valve, thermocouple, pressure indicator (digital & analogue),
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
what is the difference between attemperator and desuperheater ?
How to calibrate H2s Dectector
it is possible to check the fail safe condition in pressure transmitter. if possible how?
How RAL(Rotary air lock)works in cement industry?
what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.
Questions on flow meters,few questions on HART protocol,
please send the sample qustion paper for iocl written test ..
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
I faced several time siemens ps2 positioner automatically getting Chang in it's set point direction after auto calibration So is there any causes biside this or any permissives ?
1)How many tpes of vibration probe and how many tpyes of vibration. 2)how we can calibrate a vibration probe with tk3 3)what is RMS value in vibration measuring application and how we calculate it.
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?
What is the GK Value in Flowmeter?
how to calculate range of level transmitter?