Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why in Digital Megger for finding Insulation resistance,-ve
is applied to core or conductor and +ve is applied to
ground.

Answer Posted / ramesharavind s

in we throw the + wire in gnd when we find the how much
current flow in gnd wire and'll then as per ohm's law we
find the resistence of gnd.

so we always connect the +ve in gnd.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the effect of earth on capacitance in 3-phase and 1- phase transmission line?

2308


WHAT ARE THE CHARACTERISTICS OF AN VOLTAG AMPLIFIER

1974


What is Long rod insulator and it's applications..? merits over the disc insulator ..?

1855


why we are not giving the zone 1 trip command to the master trip relay

1684


how current is reverse from its normal direction during the fault?

2397


1.what is difference in maintain Hz again Hz in USA ? 2.how to calculate the battery AH? 3.why are yearly maintained in transformer how many tests in required?

2725


What is the exact formula for one weber of magnetic flux?

2084


I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2389


Can you explain about Restricited earth fault protection scheme

1803


Distinguish between nuclear power station with thermal power station for initial cost, starting period, cleanliness, and transportation of fuel

1973


why do we put a transformer on soak before loading it

1081


if 3400kw slipring motor rotor shorting done and motor started on mv drive ,what will be the rotor shoring current

1629


What is the diff. between single compression and double compression gland

1938


Describe the test procedure to determine the vector group

2067


If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.

2050