If two hack saw blades, seperated by 1mm thick paper,are
connected across 230volts, and immersed in water,then they
start getting heat. This is fact,i dont know how they get
heated.Blades are not directly connected together.
Please if anybody knows the fact ,revert back to me
Answer Posted / k.prakashchandra
The water in between acts as a resistance /heater coil
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
any one can explain the stages of a knee point which is taken during ct magnetising curve.
I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.
why the field winding in dc motor is not short circuited eventhough dc supply is applied across the winding
Explain mechanical rotational system?
What is meant by analogous system?
How can calculate the rating of a alternator for a given specific load with formula
How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?
do anyone out there know where to find a compleete list on acronyms/abbreviations used in offshore electric engineering. MCB - Micro Circuit Breaker, MCCB-Mouldes Case Circuit Breaker, ELCB-Earth Lekage Circuit Breaker, ELMCB- etc.....
How to do cable earhing? whether by grounding Armour to ground or by running extra G.I wire along with cable? which one is preferred mostly amoung them? If the second one is more preferable how many GI wires to be run along with cable (1 or 2)?
How to convert 2 phase to 3 phase electricpower in induction moter?
Why do we perform an open-circuit test and short-circuit test on the transformer?
how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .
how is capacitor bank look like
what is the solution for meger test failed the MV cable?
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.