Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the flooring of substation is done with small pebbles or
stones..?

Answer Posted / dinesh

In a substation the conductors will be near in distance to
the earth, so that the flux of the conductor may cause a
shock to the person who enters the substation. so in order
to increase the resistance between the earth and
conductors, pebbels or gravels are used...

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to select a cable size for particular load?

1882


How much earthing frequency is capable?

2000


Why is remote backup preferred to local backup?

2118


Difference between ac parallel circuit and ac series circuit?

2188


What should be the percentage increase in length of the dead end clamp for bus bar conductor (Hawthorn) after hydraulic pressing and what should be the applied pressure?

2003


being an electrical engineer why you wanna come into software i have an very good academics what answer i have to give

1968


what will happen if earth of 33 kv cable (earthed system) is not connected to earthing pit?

2098


what are the steps involved in generator load test?

1612


Please explain, how to test vector group of tranformer(Delta y1) . Thank

1753


Please tell me in DETAIL about the following 3 types of fuses or recommend me a good power system protection book or a website link ? 1.Dropout Fuse 2.Striker Fuse 3.Empulsive fuse (not sure if its impulsive or explosion fuse , sorry)

2153


Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?

1774


Explain what is clipper and clamper circuits?

1236


What are books to be referred for KPTCL exam?

3727


what the function breaker failure scheme, how is it operated

1956


What is the difference between Generator Differential Relay and Transformer Differential Relay?

2334