Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how the inductor will work on dc supply?whether it will
work or not?

Answer Posted / jalapathi

if we gave a dc power to the IM winding it develops a non
variable magnetic field. bit motor does not run. bcoz there
is no relative motion between const mag field and rotor
conductor.

ex: dc solenoid coil
when we give dc power to the solenoid coil it will act as
magnet

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define settling time.

1175


Single phase and threephase power calculation

2143


What is the kiosk parts, about them and their functions ? If anybody have some PDFs files or details about this plz send it on tawhidfaisal@Yahoo.com

1933


What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA

1758


What is the method to solve circuit using source transformation?

1153


Explain the function and difference of Restricted earth fault, simple earth fault and sensitive earth fault with connection diagram.

2664


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2130


Difference between field rheostat and armature rheostat.

1232


What is the necessary condition for stability.

1219


how to calculate the no load current in transformer?

2522


how to revers the direction of single phase motor

964


what is (+) and (-) in generator field detector stand for?

1848


Do Phase angle measurement have any application in freq/harmonics measurement? If so how?

1945


What is the safety of UPS?

2042


what is the difference between ups & inverter

7164