Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the effect if power factor is above 1 or unity.

Answer Posted / rahul bhimani

power factor will be unity when Kw(real power)=KVA(reactive power).i.e P.F=1 ,Now if P.F >1 means reducing KVA ,so one point comes only Kw flows through the line.
Another way power = VI(cos@) ,where cos@ is P.F & @ is angle between voltage and current . so Power =VI when @=0 ,Power =0 for @=90 ,power = -VI for @=180. That means if phase angle between V & I is vary so power delivered to the load will be vary.So pure real power flow only if cos0=1.Means V&I in phase.

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Mention the disadvantages of low power factor? How can it be improved?

1148


What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?

1771


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1654


WHAT IS THE WINDING PROCEDURE OF ELECTRICAL MOTOR

3974


what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY

2198


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9198


Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?

1917


what is difference between elr and R eartl realy.

2629


what are the tests comes under the type test, what tests comes under routine tests.

1453


What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)

3640


how diside ct mf exmp.200/5 ct

2178


What is current divider rule (cdr)?

1339


Explain Random and Deterministic signals?

1797


What is an order of a system.

1327


what does mean of RCT and STR in diffrential CT?

4228