What is the effect if power factor is above 1 or unity.
Answer Posted / rahul bhimani
power factor will be unity when Kw(real power)=KVA(reactive power).i.e P.F=1 ,Now if P.F >1 means reducing KVA ,so one point comes only Kw flows through the line.
Another way power = VI(cos@) ,where cos@ is P.F & @ is angle between voltage and current . so Power =VI when @=0 ,Power =0 for @=90 ,power = -VI for @=180. That means if phase angle between V & I is vary so power delivered to the load will be vary.So pure real power flow only if cos0=1.Means V&I in phase.
| Is This Answer Correct ? | 2 Yes | 2 No |
Post New Answer View All Answers
What is the function of under voltage release ?
What are the protection required for Transformer, motor, Line, Generator, capacitor, that all i have to refer which standard?(Like Transformer detail IS 2026)
List examples of current sources?
what is alluminium arm in ab conductors
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
what is high - pot test. what's its use?????
The 3 phase 400 hp 440 volt slip ring induction motor do not take one phase amps why ? The motor is running good condition
what is acceptable leakage current for 33kv cable while doing high voltage test for cable? how to calaulate the leakage current for 33kv or any rated cable?
Star Delta Diagram with full description
i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.
CBCT selection
what is difference between bus coupler and auto transfer switch
if grounding is notdone at regular intervals for long distance transmission, will the load connected at distribution end receive voltage during negativehalf cycle of the sine wave?
why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?
what is reverse power relay brief explanation and in b/w where it is connected