what's the minimum level required of SIL (safety integrity
level)to use fire and gas system?
Answer Posted / laxit
Safety integrity leve has nothing to do with F&G System.
First of all you need to do SIL study for the system.In
case if you landup in SIL-0 or 1 or 2 system you can use
relavant type of SIL system. Inshort it depends upon your
SIF/SIL workshop outcome.
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
define feed forward control loop with example and drawing?
I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?
why fuse block is not used for AI signal?
Draw a complete P&ID of a flow suction tank indicating all control & protection equipment. Indicate all its inlets and outlets. Explain the controls for this system
how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???
how u calibrate pneumatic n motorized c/v?
What is the reason PT speed not incresed in gas turbine?
Tell me the field calibration procedure step by step with diagram of pressure gauge, pressure switch, pressure transmitter, temperature switch, level switch, flow switch, flow transmitter.
please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com
A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?
flow transmeter accuracy 0.075% of full scale & find ucertainty is 0.025 % so what is maximum limit band of uncertainty
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters
the output of the common trasmitter protocol in qatar gas are the following
what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?