what is the physical phenomenon because of which skin
effect occurs ??
Answer Posted / wareagle
Skin effect is the tendency of an alternating electric
current (AC) to become distributed within a conductor such
that the current density is largest near the surface of the
conductor, and decreases with greater depths in the
conductor. The electric current flows mainly at the "skin"
of the conductor, between the outer surface and a level
called the skin depth. The skin effect causes the effective
resistance of the conductor to increase at higher
frequencies where the skin depth is smaller, thus reducing
the effective cross-section of the conductor. The skin
effect is due to opposing eddy currents induced by the
changing magnetic field resulting from the alternating
current
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
SIR, GIVE ME OPGW SAG CALCULATION FORMULA I AM DAE ELECTRICAL. THANKS
why would amp draw on neutral wire be as much as amp draw on the hot leg.
is IS says that neutral should be brought to switch box. and this one is a recomended practice
upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.
What is rotating magnetic field?Discuss elaborately.
What is the effect of atmospheric pressure & Temp; on efficiency of motor? Why NGR(Neutral Grounding Resistor) is used in 132/11 KV Transformer & how? What is the use of Auto T/F in Grid Station?
1. transformer design formula ? 2. how to calculate the primary turns and secondry turns ? 3. core types ? 4. how to find the primary current and secondry current ? 5. how to calculate the stacking factor ? 6. range of fulx density ?
WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?
why 3 phase is converted into 2 phase using electronics circuit why not 2 phases are diresctly putted from the 3 phase transformer??
hi this is hema, r there any books in particular for the preparation of the APPSC-A.E.E(electrical), if so please mail me the names ... thank u .
Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.
how is the incoming cable size calculated for a given current rating of a panel??
When we connect the large capacitor bank in series ?
WHY RATING OF VCB NOT LESS THAN 630A
i have done diploma and btech in EE and live in Chandigarh so kindly help me how can i make my competency certificate in my area.