what is the physical phenomenon because of which skin
effect occurs ??
Answer Posted / wareagle
Skin effect is the tendency of an alternating electric
current (AC) to become distributed within a conductor such
that the current density is largest near the surface of the
conductor, and decreases with greater depths in the
conductor. The electric current flows mainly at the "skin"
of the conductor, between the outer surface and a level
called the skin depth. The skin effect causes the effective
resistance of the conductor to increase at higher
frequencies where the skin depth is smaller, thus reducing
the effective cross-section of the conductor. The skin
effect is due to opposing eddy currents induced by the
changing magnetic field resulting from the alternating
current
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
Draw torque - speed curve and load curve of induction motor? mark operating point ?
diff. between tension mode & speed mode
what happen if field of dc shunt motor opens? what is function of putting res. in parallel to one phase of 3 phase IM? the power supplied by 5A source in circuit is given by------Watt.
How would you relate your key competencies to this position?
we use capister for power factor. when we use capaciter in dg circuit than defect dg. can we use capaciter bank for dg circuit
distribution is maximum done by a)radial b)network c) parallel d)b & c
What is the previous name of Cox's Bazar
What is the reason of polyphase induction motor tripping suddenly on high current during running at 70% laod? Motor IR , winding resistance & inductance balance. Motor no load current is balance and ok as per mgfr. data.
# 4 hi friends i m from electrical branch and seeking for tech. + apti. both papers of hpcl plz get it available as soon as possible my email id is sumit_lig189@yahoo.co.in
what is your majour contributions in your present job
Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.
sail kaott diploma ece ke interviw me qus.kis parkar ke aate hai aur G.S me kya puchate hai kya sameedyaan me kis parkar ke qu.puchate hai
What is the permissible limit of shaft voltage for 6.6 KV motors ? Why? Is there any standard is available?
advantages and disadvantages of inverse definite minimum time RELAY
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?